Product

TP5500

TPUNB terminal DTU, 470–510 MHz, 26 dBm, RS485 + RS232, IP65 outdoor housing, 5–28 V supply.

Frequency
470–510 MHz
TX power
26 ± 1 dBm
Sensitivity
-116 dBm @19.2 kbps, 470 MHz
Package
116 × 85 × 41 mm

Request datasheet & pricing →

Technical specifications

Radio

TP5500 Radio specifications
Operating frequency470–510 MHz
Channel bandwidth≤200 kHz per carrier
Symbol rate2.4 kbps / 19.2 kbps / 76.8 kbps
Transmit power26 ± 1 dBm
Channels1
Receiver sensitivity-116 dBm @19.2 kbps, 470 MHz
Operating modesBidirectional transparent, unidirectional receive, unidirectional transmit

Hardware

TP5500 Hardware specifications
InterfacesRS485 ×1; RS232 ×1; DC 12 V input ×1; TPUNB SMA female ×1; magnetic mode switch ×1
Supply voltageDC 12 V (5–28 V wide range)
Power consumption≤1 W
Dimensions116 × 85 × 41 mm
Weight<0.25 kg
MountingWall mount or DN35 DIN rail
Protection classIP65
InstallationOutdoor

Environmental

TP5500 Environmental specifications
Operating temperature-40 °C to +70 °C
Storage temperature-40 °C to +85 °C
ESD immunityAir discharge ±15 kV, contact discharge ±10 kV

Overview

The TP5500 is a TPUNB terminal DTU built for outdoor installations: it takes RS485 or RS232 data on the wired side and carries it over a TPUNB narrowband link in the 470–510 MHz band. Transmit power is 26 ± 1 dBm with a receiver sensitivity of -116 dBm at 19.2 kbps, and the link supports 2.4, 19.2 and 76.8 kbps symbol rates.

It runs in three modes: bidirectional transparent forwarding (the default), unidirectional receive into the serial port, and unidirectional transmit from the serial port. Both serial ports are available at once, and the mode is switched with a magnetic button so the housing stays closed in the field. Supply is DC 12 V with a 5–28 V range, drawing 1 W or less.

The enclosure is 116 × 85 × 41 mm and rated IP65 for outdoor mounting on a wall or a DN35 DIN rail, with an operating range of -40 °C to +70 °C and ESD immunity of ±15 kV air / ±10 kV contact. It suits metering, monitoring and industrial control points where a serial device needs to reach a TPUNB base station without cabling.