Product

TP8901

1U edge AI video gateway for substations: 8K video decode, 6 gigabit ports with 802.3at PoE, isolated RS485, TPUNB radio and grid protocols from Modbus to IEC 104 and GB/T 28181.

Request datasheet & pricing →

Technical specifications

Compute

TP8901 Compute specifications
CPU2 GHz
AI acceleration6 TOPS
Memory8 GB
Storage32 GB
Operating systemLinux, Docker containers supported

Video

TP8901 Video specifications
DecodingMPEG-1/2/4, H.263, H.264, H.265, AVC, HEVC, MVC, VC-1, VP8, VP9, AV1, AVS2 — up to 8K60
EncodingH.264, H.265 — up to 8K30

Interfaces

TP8901 Interfaces specifications
Ethernet6 × 10/100/1000 M — 1 management, 5 service; PoE 802.3at, 48 V output
Serial8 × RS485 + 2 × RS232, isolated (2 RS232 share RS485 terminals, selectable)
Digital input4 × dry contact alarm input
Digital output4 × relay control output
Cellular1 × 4G, public or private network, dual SIM
WirelessTPUNB 470 MHz; Wi-Fi
VideoHDMI ×1
USBUSB 3.0 ×1, dual-layer USB ×1, OTG ×1

Power

TP8901 Power specifications
SupplyAC/DC 220 V, 50 Hz, −20 %/+20 %
Consumption≤35 W

Mechanical

TP8901 Mechanical specifications
Form factor1U rack, 430 × 300 × 44.5 mm
CoolingFanless

Environment

TP8901 Environment specifications
Operating temperature−40 to 85 °C
Humidity20–90 % RH, non-condensing
Ingress protectionIP40

Protocols

TP8901 Protocols specifications
SouthboundModbus RTU, Modbus TCP, Q/GDW 12184, GB/T 28181-2016, GB/T 28181-2022
NorthboundModbus RTU/TCP, DL/T 634.5 104-2009, Kaihong API, MQTT power IoT protocol, GB/T 28181-2022, Q/GDW 10517.1-2019

Overview

TP8901 is the substation variant of the 1U edge gateway. The hardware platform is the same class — 2 GHz CPU, 6 TOPS, 8 GB RAM, 32 GB storage, fanless, IP40 — but the video path and the protocol list are built for a distribution substation rather than a campus: up to 8K60 decode across MPEG, H.264/H.265, AV1 and AVS2, five service gigabit ports with 802.3at PoE to power the cameras directly, and isolated RS485.

What it replaces is a cabinet full of single-purpose boxes. Environmental monitoring (temperature, humidity, SF6, oxygen, ozone, smoke, water level) comes in over Modbus; security and equipment monitoring come in over DI and RS485; video comes in over GB/T 28181; and TPUNB carries the wireless sensors that comply with Q/GDW 12184. The gateway applies the thresholds, runs the linkage rules — humidity to air-conditioner, water to pump, gas to fan, smoke to power and video, door contact to lighting and arming — and reports northbound over IEC 104, MQTT or the Kaihong API.

The analytics list is tuned to the site: hard-hat detection, small-animal intrusion, person-down, area intrusion, workwear recognition, plus meter-reading and switch-state recognition for equipment inspection. Docker support means an application can be deployed alongside the built-in functions, and recorded inspection reports are pushed to the master station on a schedule.