Industry Insights

Gateway capacity tables: 50 nodes at 4 s vs 30 s

A capacity table hides three variables: exchange airtime, channel count and load factor. Inverting the numbers shows where a 4 s cycle actually breaks.

The table gives you a count, not a curve

Open the datasheet for a 470 MHz gateway and the capacity line reads like a fact: "DSME: 50 typical at a 4 s service cycle; contention: 300". Two numbers, two scheduling modes, and not one unit that helps you plan a real project. A metering rollout does not need 50 terminals at 4 s. It needs 180 terminals at three different cycles, and that sentence says nothing about whether they fit.

The number is a single point on a surface with three axes: how long one poll exchange takes on air, how many channels the gateway actually runs, and what load factor the vendor considered safe. Move any one of them and the count changes. The good news is that the table can be inverted. Do that and you get all three variables, which means you can answer your own capacity question without another round of email with the vendor.

Chart of terminal count against service cycle for one, two and four channels, with the datasheet points marked

Invert the number before you trust it

Capacity is not a property of the radio. It is airtime divided by demand. In one service cycle of length T, a gateway with C channels owns C × T seconds of transmission time. A fleet of N terminals asking once per cycle consumes N × t_ex seconds, where t_ex is the airtime of one complete exchange: poll, report, acknowledgement and the gaps between them.

u = N * t_ex / (channels * cycle)

Everything in that equation is measurable except t_ex. So start from the frames. For the TP2000-M4D01, the datasheet gives 2.4 kbps uplink and 19.2 kbps downlink in mode 1, four channels, and −122 dBm sensitivity. Assume a 12-byte PHY overhead (4-byte preamble, 4-byte sync, 2-byte header, 2-byte CRC), a 4-byte ACK, a 10 ms turnaround at each direction change and a 5 ms scheduling guard. Take a 24-byte application report, which is what a four-register meter frame looks like once you pack address, sequence, timestamp, values and status.

Element

Direction

Bytes on air

Rate

Airtime

Poll

gateway to terminal

20

19.2 kbps

8.3 ms

Report

terminal to gateway

36

2.4 kbps

120.0 ms

ACK

gateway to terminal

16

19.2 kbps

6.7 ms

Turnarounds

both

two at 10 ms

20.0 ms

Scheduling guard

5 ms

5.0 ms

Total

160.0 ms

160 ms per terminal. Now go back to the table. Fifty terminals at a 4 s cycle on four channels consume 50 × 0.16 = 8 s of air per 4 s cycle, against a pool of 4 × 4 = 16 s. That is a 50 % load factor. The number in the datasheet is therefore not the radio's ceiling; it is the point where half the air is still free for retries, beacons, broadcast and whatever commands your head-end decides to send at 3 a.m.

That 50 % is an assumption, and it is worth testing its sensitivity. If you believe the vendor meant a fully loaded pool, the same two numbers imply a 320 ms exchange, which at 2.4 kbps uplink is roughly a 74-byte report. Both readings exist in the field. The 24-byte reading leaves you half the pool; the 74-byte reading leaves you none. Which one you are buying is decided by your own payload, not by the datasheet.

The uplink owns the whole budget

Of those 160 ms, 120 ms is the uplink report. The poll and the ACK travel at 19.2 kbps and cost less than 15 ms together. At 2.4 kbps one byte takes 3.33 ms, so the entire capacity conversation is really a conversation about how many bytes your terminal sends upward.

Uplink airtime against application payload at 2.4 and 76.8 kbps, with the 160 ms slot budget drawn as a line

Read the blue curve: 24 bytes fits the budget with the overheads already paid. Ten more bytes costs 33 ms, which is a fifth of the budget, and pushes the same four-channel gateway from 50 terminals to 43 at a 4 s cycle. A text-encoded report is the classic way to lose a third of your capacity without noticing: 80 bytes of JSON is 307 ms of uplink, a 347 ms exchange, and 23 terminals at 4 s instead of 50. Nothing in the RF chain changed. The payload did.

This is also why the second column of the capacity table is not a different radio. It is the same air, spent more slowly.

The second column is the same budget, stretched

Numbers again, with the 160 ms exchange: 300 terminals at a 30 s cycle demand 300 × 0.16 = 48 s of air per 30 s cycle, against a pool of 4 × 30 = 120 s. That is 40 % load, not 300 % of anything. The extra terminals do not come from a more efficient modulation or a cleverer scheduler; they come from asking each terminal 50 times less often.

Per second, the two columns are almost the same: 12.5 exchanges per second in DSME and 10 per second in contention.

Mode in the table

Terminals

Cycle

Exchanges per second

Load on four channels

DSME time-slotted

50

4 s

12.5

50 %

Contention

300

30 s

10.0

40 %

The interesting part of that table is the 40 %. Random access converts collisions into lost airtime, so a contention network cannot operate as close to the ceiling as a scheduled one. The classical numbers are unforgiving: textbook pure ALOHA puts successful frames in 18.4 % of the air, and aligning transmissions into slots only doubles that to 36.8 %. A 40 % load sits just above the slotted ceiling, which means the contention mode in this gateway cannot be plain slotted ALOHA; it must listen before it talks, or back off faster than the textbook.

That distinction is not academic. European short-range rules take the same view: ETSI EN 300 220-2 caps transmitter duty cycle by band, then exempts equipment that uses "polite spectrum access" — the regulator agreeing that listening first buys you more airtime. If a vendor quotes a contention figure without saying whether the MAC is carrier-sense or pure random access, assume the worst case and plan your cycle for the slotted number: at 18.4 % the same four channels carry about 140 exchanges per 30 s, not 300.

Same radio, half the channels

The cleanest way to see that channels, not sensitivity, set the count is to compare the gateway module with the TP2208 indoor unit. Same 2.4 kbps uplink and 19.2 kbps downlink, same −122 dBm sensitivity, 17 dBm in both, but two channels instead of four and a 470–490 MHz tuning range.

The TP2208 is rated for 100 terminals or more, with no cycle attached. Run the same inversion: 100 × 0.16 = 16 s of air, against a pool of 2 × T. At a 4 s cycle that is 200 % — impossible. Even at a fully loaded pool the implied cycle is 8 s, and at the same 50 % design factor it is 16 s. So "≥100 terminals" on this unit is an 8-to-16-second claim, not a 4-second one. Buy it for a 4 s leak-detection loop with 100 nodes and you will measure a p95 near 8 s and blame the radio for something the channel count decided.

Channels

4 s cycle

8 s cycle

12 s cycle

30 s cycle

1

13

25

38

94

2

25

50

75

188

4

50

100

150

375

Terminals at a 50 % load factor, 160 ms exchange. The table is the datasheet's own numbers, re-read: the 50 at 4 s is the bottom-right cell of the four-channel column, and everything else follows from it.

What mode 2 buys, and what it charges

The same datasheet offers a second mode at 76.8 kbps in both directions, with sensitivity falling from −122 to −109 dBm. The exchange drops from 160 ms to about 32 ms, so the four-channel pool carries roughly 246 terminals at a 4 s cycle and the same 50 % load, instead of 50. That is 4.9 times the capacity.

It is not free, and the price is set by physics rather than by marketing. Thirteen decibels of receiver sensitivity is a factor of 4.5 in free-space distance, since distance follows the inverse of the ITU-R P.525 free-space law: 10^(13/20) = 4.47. Capacity up 4.9×, reach down 4.5× — almost the same number. Mode 2 does not create airtime; it converts link budget into airtime at roughly one to one. If your site has margin to spare in the link and none in the schedule, the trade is a good one. If the site is already at the edge of range, mode 2 will turn a capacity problem into a coverage problem, which is the more expensive of the two.

Failure modes the table hides

Five things go wrong in the field that a single capacity number cannot warn you about.

Queueing looks like packet loss. Once demand exceeds the pool, the gateway does not drop frames, it defers them. Acknowledgement rates stay above 99 % while p95 latency climbs past the nominal cycle. Teams then add retries, which adds airtime, which makes it worse. Distinguish the two before touching the RF: loss shows up as missing ACKs on specific nodes, queueing shows up as late ACKs on all nodes at once.

Retries inflate demand quadratically. A 5 % retry rate is 8 ms of extra air per exchange. At the edge of coverage, where retries reach 20 %, you add 32 ms to a 160 ms exchange, and the 50 % design point becomes 60 %. Nodes at the cell edge are the ones that retry, so the pool is consumed unevenly and the loaded cell fails first.

Fast classes eat the pool. A leak-detection class of 10 nodes at a 1 s cycle demands 10 × 0.16 = 1.6 s of air per second, which is 40 % of a four-channel pool for 5 % of the fleet. The slowest class is almost free by comparison: 80 nodes at 60 s is 0.21 s per second. Plan by class, never by terminal count.

Join bursts after a reboot. Three hundred terminals re-joining after a gateway restart is 300 exchanges in a burst, or 48 s of airtime at once. The first post-reboot cycle looks like an outage even when nothing is broken. Randomised join backoff is the fix; without it, a firmware update becomes a support ticket.

Clock drift in a scheduled mode. A 20 ppm oscillator drifts 1.7 s per day. If the slot is 20 ms wide, 10 ms of misalignment is enough to miss it, and at 20 ppm that takes 500 s. DSME needs a periodic beacon to stay aligned, and the beacon is airtime you must budget for — one more reason the 50 % design factor exists.

A worked plan for 180 mixed terminals

Take a real fleet: 40 nodes on a 4 s leak loop, 60 nodes reporting valve state every 12 s, and 80 nodes read once a minute. On a TP2000-M4D01 at mode 1, the airtime demand is 40/4 × 0.16 = 1.60 s per second, 60/12 × 0.16 = 0.80, and 80/60 × 0.16 = 0.21. Total 2.61 s per second against a 4 s pool — 65 %.

Stacked bars comparing 2.61 seconds per second of demand with 40 nodes at 4 s against 1.81 seconds per second with the same nodes at 8 s

Sixty-five per cent is not a plan, it is a queue waiting for a busy hour. Moving the leak class from 4 s to 8 s halves its share to 0.80 s and the total drops to 1.81 s per second, or 45 %. Nothing else in the network changes: same gateway, same channels, same payloads, same radio mode. One scheduling decision bought the margin back.

Class

Nodes

Cycle A

Airtime A

Cycle B

Airtime B

Leak detection

40

4 s

1.60 s/s

8 s

0.80 s/s

Valve state

60

12 s

0.80 s/s

12 s

0.80 s/s

Meter read

80

60 s

0.21 s/s

60 s

0.21 s/s

Total

180

2.61 s/s (65 %)

1.81 s/s (45 %)

The alternative is simpler but blunter: put all 180 on one 16 s cycle, which lands at 180 × 0.16 / 16 = 1.80 s per second, the same 45 %. Uniform cycles are easier to operate and easier to reason about; tiered cycles exist because a leak alarm that arrives 16 s late is a different product from one that arrives in 4 s. Decide that requirement before you decide the schedule.

How to verify on site

Do not trust the online-rate figure on the dashboard; it measures association, not latency. Measure the exchange instead.

  1. Log the time from poll transmission to ACK for every terminal for one hour, then compute p50 and p95 per node. A healthy 4 s network sits near 0.3 s at p50 and under 4.2 s at p95.
  2. Compare p95 with the nominal cycle. If p95 is below the cycle but has a long tail, you are queueing and the pool is full. If p50 is fine and a subset of nodes miss ACKs, you have an RF problem on those nodes.
  3. Sweep the fleet size. Add ten terminals at a time and watch the knee. It should appear near the load factor you designed for; if it appears at half the expected count, your payload is bigger than you think or your retries are higher.
  4. Read the retry counter per node, not in aggregate. Edge nodes with 15–20 % retries are consuming airtime the plan never allocated.
  5. Measure the largest payload you actually send, not the one in the design document. Every 10 bytes of uplink is 33 ms, and the exchange scales linearly with it.

The arithmetic you need fits on one line, and it is worth keeping next to the commissioning sheet:

t_ex    = t_poll + t_report + t_ack + 2 * t_turn + t_guard
N_max   = channels * cycle * load_factor / t_ex

Feed it the measured t_ex rather than the datasheet's, and the same equation tells you what the network will do after the next fifty meters are added. The 12-point commissioning checklist covers the rest of the acceptance work, and the polling derivation for a 100-node TPUNB network goes through the single-cell case in more detail. If you want the range side of the same datasheet, the five numbers that decide link budget is the companion piece: this article is about the schedule, that one is about the distance. The catalogue on /products lists the channel count for every gateway we ship, because it is the specification that decides the cycle.

Can I just buy a gateway with more channels?

Up to a point, yes: capacity scales linearly with channel count, so two gateways of two channels carry the same load as one of four. The ceiling is spectrum and self-interference, not the number in the datasheet. Four carriers inside a 200 kHz-per-carrier plan at 470–510 MHz is already a tight allocation, and co-locating two gateways means antenna separation and a channel plan, not just another box.

Does mode 2 at 76.8 kbps solve the capacity problem?

It multiplies exchanges by about five and divides free-space reach by about 4.5. If your link margin is comfortable, it is the cheapest capacity you can buy. If your sites are already marginal, it moves the failure from the schedule to the coverage, where it is harder to fix.

Why does my dashboard show 99 % online while reports arrive late?

Because association and delivery are different measurements. A queued network acknowledges everything and delivers late; an online-rate counter cannot see the queue. Log poll-to-ACK time per terminal and the latency distribution will show it within one cycle.

Is the 4 s cycle in the datasheet a guarantee?

It is a design point at roughly 50 % load with a compact payload. Treat it as the cycle at which the vendor expects normal operation, and verify it with your own payload and your own retry rate. If your report is 80 bytes, the same hardware is a 23-terminal gateway at 4 s — and no amount of tuning changes the arithmetic.