Industry Insights

Five datasheet numbers that actually decide your range

Transmit power is the number buyers read first and the one that matters least. Five rows in a 470 MHz datasheet decide the link — and two are usually missing.

Two radios, nine decibels of signal, one surprise

A buyer comparing three 470 MHz radios sees 17 dBm, 20 dBm and 26 dBm on the first line of three datasheets. The instinct is to take the 26 dBm unit and stop reading. Then the quote comes back: the 17 dBm part is a module on an LCC pad, the 20 dBm part is an indoor box with an RS485 port, and the 26 dBm part is an IP65 outdoor unit. Nine decibels separate the loudest from the quietest, which sounds like a factor of eight in power and therefore, surely, a much longer link.

It is not. Range is not set by transmit power. It is set by one subtraction, and that subtraction needs five numbers — two of which are routinely missing from the summary table and one of which is usually quoted in a way that makes it incomparable with the next datasheet.

Free-space and derated reach for four datasheet pairs, all at 470 MHz

The chart above is that subtraction applied to four real datasheet pairs, all on the same band. The widest and narrowest are 15 dB apart, which is a factor of 5.6 in free-space reach — not because the transmitter is louder, but because the receiver is quieter and the rate is lower.

The five numbers, and the trap inside each

Every datasheet has a "RF characteristics" table. Five rows in it decide the link; the rest decide whether the product survives the site.

Number

What the sheet says

What you actually need

The trap

Operating frequency

470–510 MHz

The band edges, and whether both ends tune the same sub-band

"Configurable" can mean the factory sets it, or that you must set it; a unit tuned to 510 MHz and a unit tuned to 470 MHz are 40 MHz apart and will not hear each other

Transmit power

26 ± 1 dBm

Conducted power, at which connector, with what tolerance

±1 dB on both ends plus cable loss is 4 dB of stack-up before the site adds anything

Receiver sensitivity

−116 dBm

Sensitivity at the rate and error rate you will run

A number with no rate attached cannot be compared with anything

Channel bandwidth / symbol rate

≤200 kHz, 2.4 / 19.2 / 76.8 kbps

Which rate gives which sensitivity, and which rate your protocol actually needs

The fastest rate is usually the one that quietly costs 4 dB

Antenna interface

SMA female, or IPEX / LCC pad

Gain at both ends, plus the cable between radio and antenna

A module's IPEX pigtail and a box's SMA bulkhead are not the same 0 dB

Two of those five are about the receiver, and the receiver is where the interesting numbers live. Transmit power is easy to buy: every extra 3 dB doubles DC current and usually needs a bigger heatsink or a bigger battery. Sensitivity is bought once, in the front end and the filter, and it is free at run time. That asymmetry is why the 17 dBm module with −120 dBm sensitivity can out-reach the 20 dBm box with −111 dBm sensitivity by a factor of two — and it does, on paper, by 6 dB.

One subtraction replaces all the adjectives

The link budget is a single line:

budget (dB) = P_tx − L_cable_tx + G_tx + G_rx − L_cable_rx − S_rx

Everything is in dB or dBm, so there is nothing to convert. P_tx is the conducted transmit power, S_rx is the receiver sensitivity at the rate you will run, the G terms are antenna gains in dBi and the L terms are cable and connector losses. The result is the maximum path loss the link can absorb.

Path loss at 470 MHz over a clear line of sight comes from the free-space formula, which is what ITU-R P.525 tabulates: 32.44 + 20·log₁₀(f in MHz) + 20·log₁₀(d in km). At 470 MHz that collapses to 85.88 + 20·log₁₀(d), so 1 km costs 85.9 dB and every doubling of distance adds 6 dB.

import math

F_MHZ = 470.0

def fspl(d_km, f_mhz=F_MHZ):
    return 32.44 + 20 * math.log10(f_mhz) + 20 * math.log10(d_km)

def budget(tx_dbm, sens_dbm, l_tx=0.0, l_rx=0.0, g_tx=0.0, g_rx=0.0):
    return tx_dbm - l_tx + g_tx + g_rx - l_rx - sens_dbm

def reach_km(b_db, f_mhz=F_MHZ):
    return 10 ** ((b_db - 32.44 - 20 * math.log10(f_mhz)) / 20)

print(round(budget(26, -116), 1), round(reach_km(142.0)))   # 142.0  640

Run it and you get a number in kilometres that no one should ever quote to a customer. That is the second half of the lesson: free-space reach is a comparison tool, not a prediction. A 640 km answer means the radio is not the limit — the site is.

Three radios from one catalogue, read the same way

Here are the same five numbers pulled from the published specifications of three Techphant radios from the catalogue, then reduced to a budget and a distance. Nothing below is estimated; the transmit power, sensitivity and rates are the ones printed on each product page.

Radio

TX power

Sensitivity (quoted rate)

Budget

Free space

With 20 dB derating

TP5500 outdoor DTU

26 ± 1 dBm

−116 dBm @ 19.2 kbps

142 dB

640 km

64 km

TP1107-MP36 module

17 dBm

−120 dBm @ 19.2 kbps

137 dB

360 km

36 km

TP5301 indoor box

20 ± 1 dBm

−111 dBm @ 19.2 kbps

131 dB

180 km

18 km

TP5301, same box at 76.8 kbps

20 ± 1 dBm

−107 dBm @ 76.8 kbps

127 dB

114 km

11 km

Three things fall out of that table that the summary rows do not tell you.

First, the 26 dBm unit is only 5 dB ahead of the 17 dBm module, because the module's receiver is 4 dB better. Five decibels is a factor of 3.5 in free space and 1.8 in the derated column — real, but not the "nine dB louder" the headline suggests.

Second, the 20 dBm box is the weakest link in the family despite being the middle power. Six decibels behind the module, eleven behind the DTU. If you picked it by transmit power alone, you picked the shortest link.

Third, the same box loses 4 dB simply by being run at 76.8 kbps instead of 19.2 kbps. Four decibels is 1.58× in distance; the four-times-faster rate costs you a third of your reach. That trade is invisible if you only read the sensitivity row, because the row only quotes one rate.

Sensitivity without a data rate is not a number

The TP5301 datasheet is unusually honest: it gives both rates, −111 dBm at 19.2 kbps and −107 dBm at 76.8 kbps. That pair is the most useful thing on the page, because it lets you calibrate everything else you read.

Quoted sensitivity against symbol rate, with the 3 dB per doubling rule of thumb

The rule of thumb is 3 dB per doubling of rate: the receiver's noise bandwidth has to grow with the data, so the noise floor rises with it. Four times the rate should therefore cost 6 dB. The TP5301 shows 4 dB. The two missing decibels are real engineering — the channel filter does not have to grow in proportion to the symbol rate when the carrier is capped at 200 kHz, and a better demodulator recovers part of the rest.

The practical consequence for a spec comparison: a datasheet that says "−120 dBm" without a rate is telling you the best number it ever measured, probably at 2.4 kbps. Compare it against a −111 dBm part quoted at 19.2 kbps and you are comparing an eight-times-slower link with a real one. Put both on the same rate first, then compare.

A thirty-second plausibility check on any sensitivity claim

Sensitivity is not a free parameter. It is the noise floor of the receiver plus the signal-to-noise ratio the demodulator needs:

S (dBm) = −174 dBm/Hz + 10·log10(B) + NF + SNR_min

That is the standard thermal-noise form; ITU-R P.372 is the reference for what the ambient noise actually looks like once you leave the shielded room. Turn the equation around and any sensitivity claim becomes a statement about two unknown numbers, NF and SNR_min:

Quoted figure

Assumed filter bandwidth

Implied NF + SNR

Verdict

−116 dBm (TP5500)

25 kHz

14 dB

Plausible: 6 dB noise figure, 8 dB demodulator threshold

−111 dBm (TP5301, 19.2 kbps)

25 kHz

19 dB

Conservative — a front end with margin, not a heroic claim

−120 dBm (TP1107-MP36)

25 kHz

10 dB

Aggressive but achievable with a narrow filter and a good LNA

−116 dBm, if measured in 200 kHz

200 kHz

5 dB

Not achievable without coding: it implies a 0 dB noise figure

The last row is the test that matters. A claim of −116 dBm in a 200 kHz channel would require the receiver to add no noise at all and the demodulator to work at a negative SNR, which is exactly what coding is for — and a module datasheet will say "with coding" if it means it. When the arithmetic gives 5 dB of headroom for noise figure plus threshold, the number was measured in a narrower filter than the channel width on the same page. Ask which bandwidth, and the comparison becomes honest again.

Where a correct datasheet still gives you a short link

Everything so far assumes the five numbers are applied to the right link. Four things break that on site.

Cable loss is charged twice. A 3 m run of RG-58 at 470 MHz is about 1.8 dB, and two connectors add roughly 0.4 dB — call it 2.2 dB. That is 29% of the reach the datasheet promised. It appears on the transmitter side as lost power and on the receiver side as lost sensitivity, and it is the single most common reason a link that computed to 18 km dies at 6.

Antenna gain is not symmetric by default. A half-wave dipole is 2.15 dBi, not 0 dBi. A 5 dBi collinear buys 5 dB in the horizontal plane and takes it away vertically, which is fine on flat ground and useless on a slope. And a module with an IPEX pad has no connector loss at all until you add the pigtail, which is where the box's SMA bulkhead already paid.

The noise floor is not the one in the lab. A pump house, a substation or a welding bay raises the ambient noise well above thermal. The receiver still needs the same SNR, so the effective sensitivity degrades by however much the noise rose — 6 to 10 dB is ordinary in a plant, and no datasheet can quote it for you.

Tolerances add up. ±1 dB transmit power at each end, 2.2 dB of cable, 1 dB of ageing in the antenna, 2 dB of connector contamination after two wet seasons: 7 dB of stack-up, which is half your reach. Budgets below 10 dB of margin are not budgets, they are hopes.

Distance gained per decibel of link budget, from a 131 dB baseline

The curve is the point: decibels are multiplicative, so the first one and the tenth one are worth the same 12% of reach. That is why a 2.2 dB cable, a 1 dB tolerance and a 2 dB connector are not small print — each of them is a tenth of the site's range, and they are all paid in the same currency.

Worked example: a 6.5 km run to a pump house

A water utility needs one reading per minute from a pump house 6.5 km from the gateway, line of sight over fields, one wall at each end, a 3 m antenna cable at the gateway and a 1.6 m cable at the pump house.

Free-space loss at 6.5 km and 470 MHz: 85.88 + 20·log₁₀(6.5) = 102.1 dB.

Radio

Budget

Margin at 6.5 km

Margin if the site costs 20 dB

76.8 kbps available

TP5500

142 dB

39.9 dB

19.9 dB

Yes

TP1107-MP36

137 dB

34.9 dB

14.9 dB

Yes

TP5301 @ 19.2 kbps

131 dB

28.9 dB

8.9 dB

Yes, at 4 dB penalty

TP5301 @ 76.8 kbps

127 dB

24.9 dB

4.9 dB

—

At 6.5 km every option closes in free space, which is why this kind of run "works" in a quotation and then fails in February. Add the derating and the picture separates: the indoor box at 76.8 kbps has 4.9 dB left, which is inside the tolerance stack-up above; the same box at 19.2 kbps has 8.9 dB, which is thin; the module has 14.9 dB; the outdoor DTU has 19.9 dB.

Then apply the cables honestly. The DTU with 2.2 dB of gateway cable and a 2.15 dBi dipole comes to 141.9 dB — the cable costs 2.2 dB and the antenna returns 2.15, so the two largely cancel, which is exactly why antenna choice is worth more attention than another 2 dB of transmit power. The indoor box with 1.6 dB of cable and the same dipole lands at 131.6 dB.

If you are still deciding between this module and a finished enclosure for the pump house, the cost side of that choice is worked through in module or finished DTU. One reading per minute at 19.2 kbps is roughly 5 ms of airtime every 60 s: a duty cycle near 0.01%, so the 1.9 A transmit current of the module costs almost nothing on average — 55 mA of receive current dominates. That is the sixth number, and it decides the battery, not the link.

What to measure in the first hour

The numbers above are only as good as the derating you chose, so measure the derating once and reuse it for every site in the same terrain.

Measurement

How

What it tells you

Received level at a known distance

One fixed transmitter, one receiver moved 200 m, 1 km, 2 km, log the reported level each time

The actual path-loss slope for that terrain, instead of the free-space 6 dB per doubling (how to read those levels)

Noise floor with the transmitter off

Same receiver, same antenna, key nothing

Whether the site is thermal-limited or noise-limited, in dB

Both directions

Swap the roles of the two ends

Asymmetric links hide behind a good downlink; the uplink is usually the weaker one

At the rate you will run

Repeat at 76.8 kbps if that is the production setting

Confirms the 4 dB you paid for speed

After rain and after a week

Same points, same antenna

Connector and cable degradation, the slowest failure mode to notice

Compare the measured level with the predicted one: predicted = P_tx + G − FSPL − L. If the measurement is 10 dB below prediction, stop tuning the radio — the problem is the antenna, the cable or the Fresnel zone, and no amount of budget will fix a cable that has water in it.

FAQ

Is a higher transmit power always the safer choice?

No. Three decibels of transmit power doubles the DC current of the output stage, and above about 20 dBm it also brings thermal and regulatory questions. Three decibels of receiver sensitivity costs nothing at run time. Between two products on the same band, the one with the better sensitivity at your operating rate usually wins, and it wins without a bigger battery.

Why do two datasheets for the same radio quote different sensitivity?

Because sensitivity is a function of three things: the filter bandwidth, the symbol rate and the error rate the measurement stopped at. A number quoted at 2.4 kbps and 1% PER is not the same specification as one quoted at 19.2 kbps and 0.1% PER, even when it is the same silicon. ETSI EN 300 220-2, the harmonised standard for short-range devices in this band, defines sensitivity against a stated error rate for exactly this reason.

Can I just fit a higher-gain antenna to get more range?

You can, and it is often the cheapest 5 dB you will ever buy — but gain comes from directivity. A 5 dBi collinear concentrates the pattern toward the horizon, which helps on flat ground and hurts when the gateway is above you or the terrain rolls. It also adds a connector and a longer cable, so check the arithmetic: 5 dBi of gain minus 2.2 dB of cable is 2.8 dB net, not 5.

How much derating should I use?

Use 10 dB for open suburban line of sight, 20 dB for a plant or a village with buildings in the path, and 30 dB when there is foliage, a metal fence or a wall at one end. Then measure it once — the first-hour table above gives the number for your own terrain, and it is the only derating figure worth trusting. Anything below 10 dB of margin after derating is a link that will fail in the season you did not test.

More in Industry Insights