wireless communication
Narrowband FSK vs chirp: what 23 dB of sensitivity costs
A spread modem at 470 MHz hears 23 dB deeper than narrowband FSK, but 20 dB of that is a 100x slower air rate. Here is what the rest costs on air and in charge.
Two meter pits sit on the same street. One reports every hour from 300 m; the other has been silent since commissioning and the crew has moved the gateway twice. Both meters use 17 dBm transmitters in the same 470–510 MHz band, and both were specified from the same catalogue page. The only difference is the modulation: one is narrowband FSK, the other is a spread-spectrum variant that the datasheets credit with 23 dB more sensitivity.
Twenty-three decibels sounds like a free upgrade. In free space it is fourteen times the range, and at a path-loss exponent of 3.5 — the sort of number you get through pit covers, soil and a concrete wall — it is still 4.5 times. But sensitivity in a datasheet is not a property of the radio in the way transmit power is. It is a property of the radio at a stated data rate, and the spread part reaches −140 dBm only by sending bits about a hundred times more slowly. This article does the arithmetic on real module numbers, splits the 23 dB into the part you actually bought and the part you paid for with time, and works out when the trade is worth signing.
Sensitivity is a rate, not a radio property
Every receiver sensitivity figure is one point on a curve. The curve is set by thermal noise and by how much energy the demodulator needs per bit:
- Noise floor in a bandwidth B: N = −174 dBm + 10·log10(B/1 Hz)
- Energy per bit at the sensitivity point: Eb/N0 = S + 174 − 10·log10(Rb)
The second line is the useful one. It converts a dBm figure into how many dB above thermal noise one bit sits, which is comparable across modulations. Do that for the five real sensitivities in our catalogue and the picture changes completely.
Module | Modulation | Air rate | Sensitivity | Implied Eb/N0 |
|---|---|---|---|---|
TP1107-MP30-L | 2-FSK | 2.4 kbps | −117 dBm | 23.2 dB |
TP1107-MP30-L | 2-FSK | 19.2 kbps | −111 dBm | 20.2 dB |
TP1107-MP30-L | 2-FSK | 76.8 kbps | −106 dBm | 19.2 dB |
TP1210-MS20 | S-FSK, SF7 | 375 bps | −127 dBm | 21.3 dB |
TP1209-MS22 | S-FSK, SF9 | 23 bps | −140 dBm | 20.3 dB |
All five land between 19 and 23 dB of energy per bit. The 23 dB gap between the top and bottom rows is not a better receiver — it is the same receiver being asked to deliver 100 times fewer bits per second. The narrowband part at 2.4 kbps is actually the most energy-hungry per bit of the five, at 23.2 dB, because its sensitivity spec carries the most design margin.
That does not make the spread part worthless. It makes the comparison honest: what you are buying is not "23 dB better", it is "23 dB better if you can live at 23 bps".
Splitting the 23 dB
Take the two extremes from the table and decompose the difference at constant transmit power (both parts are specified at 17 dBm):
- Rate difference: 10·log10(2400 / 23.4) = 20.1 dB
- Per-bit difference: 23.2 − 20.3 = 2.9 dB
- Total: 23.0 dB

So the extra processing gain you were sold is about 2.9 dB, and the other 20.1 dB is arithmetic you could have had with any modulation that was willing to run at 23 bps. That matters because 2.9 dB is inside the error bar of most link budgets: it is half of what a single extra metre of antenna height buys you on a cluttered path, and less than the difference between a wet and a dry pit cover.
The practical question is therefore not "is spread better" but "why can't I just slow the FSK down to 23 bps and pocket the 20 dB for free?"
The crystal, not the modulation, sets the floor
You cannot, because a 23 bps 2-FSK link needs a channel about 50–100 Hz wide, and cheap crystals will not stay inside it.
A 2 ppm crystal at 470 MHz is ±940 Hz off nominal. Two independent ends — meter and gateway — put up to 1.88 kHz of uncertainty between them before temperature has done anything. A 2-FSK signal at 2.4 kbps with deviation equal to the symbol rate occupies roughly 4.8 kHz, so 1.88 kHz of error is a budget item you can design around. At 23 bps the same deviation logic yields a channel of 50–100 Hz, and the error is roughly twenty times the channel width: the two ends are simply not on the same frequency any more.
Narrowband designers solve this with a TCXO and AFC, and both are real options. A ±0.5 ppm TCXO cuts the error to ±235 Hz per end and lets you narrow the channel to about 1 kHz, which supports a few hundred bps. That is a legitimate design — but note what it did: it turned a 30-cent crystal into a one-dollar part, added warm-up time and a calibration step, and it still stops an order of magnitude short of 23 bps.
Spread modulation sidesteps the problem instead of fighting it. Because each symbol is spread over many chips, a frequency offset appears at the correlator as a phase rotation it can estimate and remove; the despreading that produces the processing gain also produces tolerance to being a kilohertz off. This is the mechanism described in the CSS tutorial literature, and it is why the last few dB and the ability to run at tens of bits per second arrive as a package. The 2.9 dB of per-bit advantage is real, but the operational advantage — you can actually hold the channel — is what you are really paying for.

What the extra gain costs
Sensitivity is paid for in seconds on air, and seconds on air are paid for in charge. Take a 24-byte report — a meter ID, a reading, a status byte, a CRC — and put it through each rate, using the transmit currents from the datasheets.
FSK packets carry 8 bytes of framing (4 preamble, 2 sync, 2 CRC) plus a 20 ms ramp; spread packets carry an 8-symbol preamble.
Configuration | Time on air | TX power | Charge per report | Reports per 1 % airtime |
|---|---|---|---|---|
76.8 kbps FSK | 0.023 s | 3.25 W | 0.004 mAh | 1565 |
19.2 kbps FSK | 0.033 s | 3.25 W | 0.006 mAh | 1090 |
2.4 kbps FSK | 0.127 s | 3.25 W | 0.023 mAh | 283 |
375 bps S-FSK (SF7) | 0.53 s | 0.66 W | 0.030 mAh | 68 |
23 bps S-FSK (SF9) | 8.53 s | 0.40 W | 0.284 mAh | 4 |

Three numbers in that table deserve to be read twice.
First, the spread part transmits at 0.40 W against 3.25 W — eight times less instantaneous power — and still uses 12 times more charge per report, because it is on air 67 times longer. Low transmit power is not the same as low energy.
Second, at one report per hour the annual charge is 0.20 Ah for the 2.4 kbps FSK part and 2.49 Ah for the SF9 part. On a 2 Ah lithium cell that is roughly a decade of transmit charge against nine or ten months, before you have counted receive time, sleep leakage or retries.
Third, look at the middle row. SF7 at 375 bps gives −127 dBm, which is 10 dB better than 2.4 kbps FSK for 6.4 times less rate — 1.9 dB of genuine per-bit advantage plus the frequency tolerance. Its charge per report (0.030 mAh) is within 30 % of the narrowband part. If a design is 8–10 dB short and needs a cheaper crystal, this row, not the SF9 row, is usually the answer.
The 1 % airtime column is arithmetic, not regulation: the actual limit on how often a node may key up is set by the band regulator and the gateway's own scheduling policy. ETSI EN 300 220-2 is the reference most European sub-GHz deployments are measured against, and it treats duty cycle as a first-class constraint rather than an afterthought. Whatever number applies to your band, the ratio between the rows stays the same — a spread node occupies the channel sixty-odd times longer for the same payload.
A worked example: the water meter in the pit
Here is the same calculation an integrator actually does. A meter sits under a cast-iron cover, in a concrete pit, 1 km from a gateway on a lamp post. Transmit power is 17 dBm on both parts. The meter antenna is a small loop inside the pit, and −6 dBi is a fair number for it once the cover is on. The gateway runs a 5 dBi omni. Cable and connector loss totals 3 dB.
Item | FSK (TP1107-MP30-L) | Spread (TP1209-MS22) |
|---|---|---|
Transmit power | +17 dBm | +17 dBm |
Meter antenna | −6 dBi | −6 dBi |
Gateway antenna | +5 dBi | +5 dBi |
Cable and connectors | −3 dB | −3 dB |
Receiver sensitivity | +117 dB | +140 dB |
Budget before clutter | 130 dB | 153 dB |
Now subtract the clutter allowance and convert the remainder to distance with the free-space formula from ITU-R P.525: A = 32.44 + 20·log10(470) + 20·log10(d), which is 85.9 dB at 1 km. A pit cover, soil and a wall are worth somewhere between 25 and 45 dB depending on how wet the season is, and a 10 dB fade margin is normal practice.
Clutter + fade allowance | FSK range | Spread range | What it means |
|---|---|---|---|
35 dB | 2.9 km | 40 km | FSK already reaches 1 km; 23 dB buys nothing |
45 dB | 0.9 km | 12.8 km | FSK misses the 1 km link; spread passes with margin |
55 dB | 0.29 km | 4.0 km | Both are hard; spread still reaches the gateway |
The middle row is the entire commercial case for spread modulation: at 45 dB of clutter the narrowband link is 10 % short and the spread link has 11 dB in hand. The top row is the entire case against it: if your path is clean and your required range is 500 m, you are paying 67 times the airtime and twelve times the charge for a link budget you did not need.
Two subtleties that change the answer. First, the budget is only as good as the weaker end — a gateway specified at −106 dBm at 76.8 kbps, like the TP2128-M1CWE, will not hear a meter that the meter can hear, so the return path sets the usable rate. Second, sensitivity is quoted at a packet error rate; if the spec is at 1 % PER and your application retries twice, your effective budget is 2–3 dB lower than the table says.
Where the extra gain pays, and where it does not
It pays when all four of these are true:
- The report is small — 32 bytes or less. Air time scales with payload, so a 512-byte log at 23 bps is 3 minutes and no duty-cycle policy will allow it.
- The interval is minutes to hours, not seconds. At 23 bps, a 1 % airtime cap allows about four reports per node per hour.
- The path is 10–20 dB short on narrowband, measured, not guessed. Measured means a packet error rate at the far end, not an RSSI reading at the near end.
- There is no time-critical downlink. Acknowledgement and retry windows at 23 bps are measured in seconds, which rules out closed-loop control.
It does not pay when:
- You are polling. A 30 s cycle at 23 bps is 28 % airtime for a single node, so one meter would already own nearly a third of the channel and ten could not share it.
- You need OTA firmware. A 64 kB image at 23 bps is six hours of continuous transmission, and no regulator will grant that duty cycle.
- Node density is the constraint. Per gateway channel, the narrowband configuration carries about 280 reports per hour at 1 % airtime against about 4 for SF9. If you have 200 meters on one gateway, spread is the wrong tool no matter how good the sensitivity looks.
- The link already works. Adding 23 dB to a link with 20 dB of margin is engineering with no return.
The honest summary is that the extra processing gain is real but small — 2.9 dB per bit — and everything else is time. Spread wins when time is the resource you have most of, which is exactly the case for a battery meter read once an hour from a pit.
Field verification, in the order that finds the problem
Datasheet sensitivity rarely survives contact with a pit, so the last step of any selection is a measurement. In this order:
- Sweep attenuation, not distance. Put a step attenuator between the meter and a test antenna and walk the link down in 1 dB steps at the real install site. Record packet error rate for 100 packets at each step; the number you want is the attenuation at which PER crosses 1 %, not the point where the link dies.
- Verify the rate the link actually negotiated. A module that falls back from 76.8 kbps to 2.4 kbps under retries changes your airtime budget by 32 times. Log the rate per packet for a day.
- Count airtime, don't estimate it. Multiply packets by the time-on-air for the rate in use and compare with the channel's duty allowance. A retry storm is invisible in an RSSI log and obvious in an airtime count.
- Test the return path separately. Send a downlink at the rate the gateway will use. A gateway limited to −106 dBm at 76.8 kbps can be the weakest element in a system whose meter is specified at −120 dBm.
- Repeat at temperature. Run the pit at −20 °C and at +55 °C. Crystal drift moves the apparent sensitivity by several dB, and the failure appears in February, not in the lab.
A short script that turns a packet log into an airtime figure keeps this honest:
# airtime per report, from the rates in this article
def fsk_toa(bits, rb, ramp=0.020):
return bits / rb + ramp
def css_toa(bits, sf, chip):
return 8 * (2 ** sf) / chip + bits / (chip / (2 ** sf))
print(fsk_toa(256, 2400)) # 0.127 s - narrowband, 24-byte report
print(css_toa(192, 9, 12000)) # 8.533 s - SF9 spread, same payloadFAQ
Is spread modulation really 23 dB more sensitive?
At the stated rates, yes — −140 dBm against −117 dBm, both at 17 dBm. But 20.1 dB of that is the rate being a hundred times lower, and only 2.9 dB is per-bit advantage. Quote both numbers or the comparison flatters the spread part.
Can I just raise transmit power instead?
Thirteen dB is the gap between 17 dBm and 30 dBm, and 30 dBm at 470 MHz is a different regulatory class with a different product certification, a bigger PA and several times the current. It also does nothing for the return path, which is usually the weaker direction. If you need 20 dB, spread buys it with time; a PA buys it with regulation and heat.
Does a lower data rate always mean longer range?
Until one of three walls: the crystal tolerance wall (below a few hundred bps a plain FSK link cannot hold its channel without a TCXO), the duty-cycle wall (airtime grows linearly as rate falls), and the latency wall (acknowledgements and retries stop fitting in the application's timing). Spread pushes the first wall back and leaves the other two exactly where they were.
Which part for a 1 km pit meter?
Measure first. If a 2.4 kbps narrowband link at TP1107-MP30-L shows better than 6 dB of margin at 1 km, keep it — its 0.023 mAh per report is hard to beat. If it is 8–15 dB short, step to SF7 at TP1210-MS20 before jumping to SF9: 10 dB of sensitivity for 6.4 times less rate and roughly the same charge. Reserve TP1209-MS22 for the pits where only 23 bps closes the link, and budget the battery for it.
The catalogue view, with the rates and sensitivities side by side, is on the product index.