TPUNB commissioning: four numbers to record before go-live
Four measurements taken on day one decide whether a TPUNB network can ever be diagnosed: noise floor, rate-correct margin, air-time load and the 24-hour peak.
Most commissioning reports read like a tick list: gateway mounted, antennas fitted, thirty nodes joined, all online. Six months later a node starts losing frames and nobody can say whether that link was ever healthy, because "online" is a state and not a measurement. When the first fault arrives, the useful question is not whether the network works, it is how much margin it had on day one and how far the floor has moved since.
Four numbers answer that question, and all four can be taken with the gateway you already installed. They cost about forty minutes on site. What follows is what each number should be, how to derive the expected value from the radio you bought, and which deviation means "interference" rather than "bad radio".
The four numbers, and what each one can prove
# | Measurement | How | Expected at 470 MHz, 200 kHz channel | Act when |
|---|---|---|---|---|
1 | Idle noise floor, both channels | RSSI in dBm with every terminal silent, 200 samples, plant running | ≈ −113 dBm (6 dB NF, rural ambient) | 3 dB above prediction, or a spread wider than 6 dB |
2 | Per-node margin at the operating rate | RSSI at the gateway, compared with rate-corrected sensitivity | ≥ 10 dB | below 10 dB, or below 6 dB on any single node |
3 | Channel occupancy | retry counters ÷ transaction air time | ≤ 0.5 Erlang per channel | above 0.6 Erlang |
4 | 24-hour maximum noise floor | the same reading logged hourly, worst hour kept | ≤ 6 dB above measurement 1 | more than 6 dB above it |
Every row has a derived expectation, which is the point. A number without an expectation is a note; a number with one is a test.
Measurement 1: the floor the radio should hear
Thermal noise in a 200 kHz channel is −174 dBm/Hz + 53.0 dB = −121 dBm at the reference temperature of 290 K. Add the receiver's own noise figure and you have the floor a healthy front end must show. At 470 MHz the site contributes surprisingly little: ITU-R P.372's outdoor measurements at 425 MHz put the median man-made noise figure at 3 dB in rural areas, 4 dB residential and 6 dB city (ITU-R P.372). Combine a 6 dB receiver with a 3 dB rural ambient and the expected reading is −113 dBm; in a city it moves to −112 dBm. Half the total noise is the radio itself.

That gives you a pass criterion that has nothing to do with opinion. If the gateway reads −105 dBm with the plant idle, the extra 8 dB is not the receiver: something in the cabinet is radiating inside your channel. Switch-mode supplies, LED drivers, variable-frequency drives and cheap PoE injectors are the usual sources, and their energy is narrow enough that one of your two channels can be clean while the other is 10 dB worse. Measure both, and keep the numbers separate — a single averaged figure hides exactly the case you need to see.
Two practical notes. Read the value in dBm from the gateway's own report, not a signal-strength bar; bars map to thresholds you cannot compare across firmware versions. And record the spread as well as the median: a steady −112 with 1 dB of variation is a healthy front end, while a median of −112 with samples swinging to −96 is an impulsive source that will cost you packets long before it moves the average.
Measurement 2: margin at the rate you will actually run
Sensitivity is only meaningful together with a data rate, because the receiver's filter passes the same noise power at every rate while the energy per bit changes. Processing gain — the ratio of the 200 kHz channel to the symbol rate — is 19.2 dB at 2.4 kbps but only 4.2 dB at 76.8 kbps. The same hardware is therefore about 15 dB less sensitive at the fast rate.
The datasheets list one sensitivity figure per model without stating the rate. You can work out which rate it belongs to. Non-coherent orthogonal FSK needs about 12.4 dB of Eb/N0 for a bit error rate of 1e-3, so a −122 dBm figure at 2.4 kbps implies a noise figure near 5.8 dB — entirely plausible for a narrowband front end. Read as a 19.2 kbps number, the same −122 dBm would demand 3.2 dB of Eb/N0, which that modulation simply cannot deliver. The published figures are 2.4 kbps figures.
Model | Sensitivity as published | Implied at 2.4 kbps | Derived at 19.2 kbps | Derived at 76.8 kbps |
|---|---|---|---|---|
TP2208 gateway | −122 dBm | −122 dBm | −113 dBm | −107 dBm |
−120 dBm | −120 dBm | −111 dBm | −105 dBm | |
−117 dBm | −117 dBm | −108 dBm | −102 dBm |
Derived columns assume the receive filter stays at the stated ≤200 kHz channel bandwidth. If the modem narrows the filter at low rates the gap shrinks, so treat them as the conservative case and confirm against your own packet-error measurements.
This is where commissioning reports go wrong most often. An installer measures −96 dBm, subtracts the −122 dBm in the brochure, writes "26 dB margin" and moves on. Running at 76.8 kbps, that node has 11 dB. Both numbers are arithmetically correct and only one is true.

The chart also shows why distance is the wrong question. At 3 km the free-space loss at 470 MHz is 95.4 dB (ITU-R P.525), leaving 47 dB of margin at 2.4 kbps — enough, on paper, for 700 km of free space. A single reinforced concrete wall costs 20 to 30 dB. So record the things that actually consume the budget: antenna height, cable type and length, how many walls the path crosses, and whether the node sits in a metal pit or a cabinet. Those four notes turn a meaningless RSSI into a diagnosis.
Measurement 3: occupancy, counted in air time
A gateway with a listed capacity of ≥100 terminals will carry 100 terminals at some poll interval and not at others. The limit is air time, not addresses.
Take a 32-byte uplink frame — preamble, sync word, header, 16 bytes of payload and CRC — and TBCC rate 1/2 coding, which doubles the bits on air. At 2.4 kbps that is 213 ms of transmit time, plus a 6.7 ms acknowledgement at 19.2 kbps and a 10 ms guard: 223 ms per acknowledged transaction. At rate 4/5 the same exchange takes 147 ms, and at 76.8 kbps it falls to 18 ms.
100 nodes polled every 30 seconds is 3.33 transactions per second, which occupies 0.74 Erlang of one channel — busy but workable, and better spread over the two channels the gateway provides. Add a 20% retry rate, which a site with a marginal node will produce, and it reaches 0.89. Poll the same 100 nodes every 4 seconds and the demand is 5.6 Erlang per channel, more than twice what both channels together can carry.

Poll interval | 2.4 kbps, TBCC 1/2 | 19.2 kbps | 76.8 kbps |
|---|---|---|---|
4 s | 36 nodes | 185 nodes | 436 nodes |
10 s | 90 nodes | 462 nodes | 1091 nodes |
30 s | 269 nodes | 1385 nodes | 3273 nodes |
Figures are two channels, zero retries, and the 223/43/18 ms transactions above. The derivation and the poll-interval trade-off in more detail are in the gateway capacity tables.
Record occupancy from the gateway's retry counter after an hour of the real poll cycle, not from the datasheet. Field retries are the cheapest early warning you will ever get: a healthy network sits near zero, and a rise from 2% to 15% over a month usually precedes the first visibly dead node by weeks.
Measurement 4: keep the maximum, not the average
A single noise-floor reading is a sample from a distribution that moves. P.372 gives time decile deviations of about +9 to +11 dB for outdoor man-made noise: the quiet hour and the busy hour are not the same site. A floor measured at 09:00 on a Sunday, or at 02:00 with the plant stopped, can be 10 dB optimistic and still be perfectly accurate.
P.372 also notes that man-made noise "often has an impulsive component" which is not Gaussian. That matters here: an impulse train raised by a welding set or a contactor can leave the average noise floor almost unchanged while destroying individual frames. This is the reason measurement 4 pairs the hourly maximum with the retry counter — one detects a raised floor, the other detects the impulses that do not raise it.
In practice: log the floor once an hour for the first 24 hours, keep the maximum and the hour it occurred, and repeat the exercise after any change to the electrical installation. If the maximum is more than 6 dB above the commissioning median, find the source before adding nodes — new nodes will not fix a noise problem, they will just give it more victims.
A worked example
The site below is a constructed example used to show the arithmetic; it is not a customer installation.
Twenty-four nodes, 3 km maximum distance, one gateway, 76.8 kbps mode, 30-second poll. The installer logs the strongest and weakest node:
- Weakest node: RSSI −96 dBm at 76.8 kbps. Correct margin: −96 − (−107) = 11 dB. Using the brochure figure of −122 dBm would have given 26 dB.
- Idle floor: measured −107 dBm against an expected −113 dBm, so 6 dB high. The extra energy appears only when the packaging line runs, which makes the drive the first suspect rather than the gateway.
- Occupancy: 24 nodes at 30 s is 0.18 Erlang per channel, 0.20 with 10% retries. There is room for another 200 nodes at this interval, and the 11 dB margin — not capacity — is the constraint.
The action that follows is specific: move one gateway 8 m closer to the far end of the line, or drop that node to 19.2 kbps and gain 6 dB of sensitivity, then re-measure rather than assume. A report that says "signal acceptable" produces no action at all.
The record sheet
One row per node, taken during commissioning and kept with the as-built drawings.
Node | Mounting / height | Antenna & cable | Rate | RSSI | Margin | Retries / 24 h | Floor max |
|---|---|---|---|---|---|---|---|
M-01 | pit lid, 0.4 m | 3 dBi whip, 2 m RG-174 | 76.8 kbps | −96 dBm | 11 dB | 3% | −107 dBm |
M-02 | cabinet door, 1.6 m | 5 dBi, 5 m LMR-200 | 76.8 kbps | −78 dBm | 29 dB | 0% | −107 dBm |
The two calculations are short enough to run from the same CSV:
import math
def margin(rssi_dbm, sens_2k4, kbps):
# processing gain relative to the 200 kHz channel
pg = 10 * math.log10(200e3 / (kbps * 1e3))
sens = sens_2k4 + (19.21 - pg) # rate-corrected sensitivity
return rssi_dbm - sens
def erlang(nodes, interval_s, airtime_ms, retry=0.0):
return nodes / interval_s * airtime_ms / 1000 * (1 + retry)
print(round(margin(-96, -122, 76.8), 1)) # 11.0 dB, not 26
print(round(erlang(24, 30, 223, 0.10), 2)) # 0.20 Erlang per channelField verification order
- Silent network, ten minutes. Power the terminals down, log the floor on both channels with the plant running. Compare with −113 dBm.
- One node at a time. Bring nodes up individually, 60 seconds each, and log RSSI, rate and retry count. This is the only moment you will ever have a clean one-node baseline.
- Run the real poll cycle for an hour. Export retry counters and compute occupancy. A network that is already at 0.6 Erlang on day one has no growth path, only a rewrite.
- Repeat the floor measurement across the day. Morning, shift change, night. Keep the maximum and its hour.
FAQ
Is the −122 dBm figure on the datasheet a 2.4 kbps number?
The arithmetic says yes. At 2.4 kbps with 200 kHz of noise bandwidth, a −122 dBm sensitivity is consistent with a 5.8 dB noise figure and the 12.4 dB Eb/N0 that non-coherent FSK needs at a 1e-3 bit error rate. Read as a 19.2 kbps figure it would require 3.2 dB, which that modulation cannot reach.
Can I just raise the transmit power instead?
Only if the link is limited by receiver noise. The gateway is specified at 17 dBm, configurable, and 3 dB more power buys 3 dB of margin in a clean channel. In an interference-limited channel it raises the floor for everyone sharing the band and usually makes retries worse. Fix the floor first; the noise measurement tells you which case you are in.
How many nodes can one gateway really carry at 4 seconds?
About 36 at 2.4 kbps with TBCC 1/2 across both channels, from the 223 ms transaction time. If you need 4-second polling with 100 nodes, the rate has to go up — at 76.8 kbps the same arithmetic gives 436 nodes.
Do I need a spectrum analyser to do this?
No for measurements 1, 2 and 3, which use the gateway's own RSSI and retry counters. You need one only to identify a source you have already detected, and even then a handheld receiver with a directional antenna is usually enough to find the cabinet it lives in. The first step is always the baseline, and that costs nothing.